YAYIDA 20:1 CONTRA ANGLE IMPLANT HANDPIECE 20:1 Dedicated professional contra-angle implant dental handpiece with stable quality and matched with the motor that meets ISO standards, providing convenience for doctors treatment.
Electric fiber optic 20:1 implant contra angle handpiece AYD-201L-CA.
Normal implant contra angle handpiece AYD-201N-CA.
Reduce 20:1 contra angle handpiece AYD-201-CA for treatment.
Parameters:
20:1 green ring
Spray type: External irrigation system
Noise:≤68dB
Gear Ratio:20:1
Bur Type:2.35mm
Description:
The top-quality and precise contra-angle for implantology and surgical applications is the IMPLANT 20:1-suitable for all drilling and shaping applications due to the high resilience of up to 70 Ncm, sufficient speed, and torque. The relatively small head diameter ensures that the dentist always has the best view of the preparation site. To meet the relevant hygiene control criteria concerning implantology and surgical applications the contra-angle can be dismantled easily without any tools.
20:1 Reduction Ratio External Irrigation System Detachable Contra Head Push Button To Exchange Burs No-slip, Highly Durable For Implant Purpose Ergonomic Comfort Grip Long Life-Span Provides Sufficient Force at Low Speed Available for Various E-type Motors in Accordance with ISO Standard Compatible with All E-type Motors. (NSK, Aseptico. W&H, Nouvag Acteon )
Instructions
1. Need to use a clean, dry, oil-free medical air compressor.
2. The air pressure is between 2.3-2.8kgf / cm2;
3. Combine the quick connector with the adapter on the bottom of the handpiece and confirm that it is locked;
4. Depress the pedal to see if the dental handpiece is operating and the nasal spray is operating normally. If everything works, you can start using your dental handpiece.
Maintenance Autoclave the handpiece following the manufacturer’s guidelines.
Be sure to place the bag paper side up in the autoclave. Allow the sterilizer to completely process through the dry cycle. This step is CRITICAL. If still damp after completion of the full sterilization cycle, leave the bagged instruments in the autoclave until the packaging is dry.
Something you need to know External cleaning
(1) Remove the bur from the dental handpiece.
(2) Clean the debris around the outlet with clean water and a brush.
(3) Use a half cup of clean water to soak at 20mm of the head and spin for 15 seconds to remove the dirt accumulated inside and outside the head.
Clean water spray.
(1) Use through-hole needles to clean spray、inner and outer nozzles to remove dirt and deposits.
(2)Clean the flush pipe inserted in each nozzle with clean water.